Để xem thông tin chi tiết về kích thước sản phẩm vui lòng download tập tin đính kèm bên dưới.
For city & industrial water, irrigation & agriculture water, oil & gas supply, sprinkler, fire hydrant, ship piping ect…
Chemical requirement
C | Mn | P | S | |
---|---|---|---|---|
Light | 0,2 | 1,2 | 0,045 | 0,045 |
Medium | 0,2 | 1,2 | 0,045 | 0,045 |
Heavy | 0,2 | 1,2 | 0,045 | 0,045 |
Physical requirement
Tensile Strength Psi (Mpa) | Yield Strength Psi (Mpa) | Elongation Psi(Mpa) | |
---|---|---|---|
Light |
320 ~460 N/mm2 33~47.2 kg/mm2) |
Min. 195 N/mm2 (20kg/mm2) |
Min. 20 |
Medium | |||
Heavy |
Test Requirement
Flattening test | Bend test | Hydrostatic test | |
---|---|---|---|
Light |
Apply for NB>DN50( 2 in. ) Weld portion H=0.75D The other side of Weld Portion H=0.6D (The Weld shall be located at 90 deg.) |
Apply for NB<DN50 Ungavalnized Tubes At Cold 180 Deg.x 6D Galvanized tubes 90Deg.x 8D |
p=53kgf/cm2 (50 bar) |
Medium | |||
Heavy |
Permissible variations in dimensions
Outside Diameter | wall thickness | length | Height of inside flash | |
---|---|---|---|---|
Light | Specified respectively in size |
* Random Lengths 4m ~7m * Mill Lengths Min. 6.4m : +150mm, -0 *Approximate Lengths: +- 150mm * Exact Lengths: +6mm, -0 |
||
Medium | ||||
Heavy |